| model | brand | output power | Input voltage | Output voltage | package | describe | |
| RPP40-243.3S | RECOM |
|
40W | 18-36VDC | 3.3VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-2405S | RECOM |
|
40W | 18-36VDC | 5VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-2412S | RECOM |
|
40W | 18-36VDC | 12VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-2415S | RECOM |
|
40W | 18-36VDC | 15VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-2424S | RECOM |
|
40W | 18-36VDC | 24VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-483.3S | RECOM |
|
40W | 36-75VDC | 3.3VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-4805S | RECOM |
|
40W | 36-75VDC | 5VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-4812S | RECOM |
|
40W | 36-75VDC | 12VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-4815S | RECOM |
|
40W | 36-75VDC | 15VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-4824S | RECOM |
|
40W | 36-75VDC | 24VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-2412D | RECOM |
|
40W | 18-36VDC | ±12VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-2415D | RECOM |
|
40W | 18-36VDC | ±15VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-2424D | RECOM |
|
40W | 18-36VDC | ±24VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-4812D | RECOM |
|
40W | 36-75VDC | ±12VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-4815D | RECOM |
|
40W | 36-75VDC | ±15VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| RPP40-4824D | RECOM |
|
40W | 36-75VDC | ±24VDC | 2x1.2 |
● 115°C Maximum Case Temperature● -40°C MinimumTemp. ● Built-in FCC/EN55022 Class B Filter● 2:1 Wide Input Voltage Range● 40 Watts Output Power● Ribbed or Baseplate Case Styles● Min. Efficiency of 87%● 3kVDC Isolation● Low Quiescent Current
|
| B7-123R3S10LF | Bothhand USA |
|
10W | 9-18VDC | 3.3VDC | DIL,SIL |
10 To 15 Watt Isolated DC-DC Converter,Wide 2 : 1 Input Range,Input Filter With Internal Capacitor
|
| B7-1205S10LF | Bothhand USA |
|
10W | 9-18VDC | 5VDC | DIL,SIL |
10 To 15 Watt Isolated DC-DC Converter,Wide 2 : 1 Input Range,Input Filter With Internal Capacitor
|
| B7-2405S10LF | Bothhand USA |
|
10W | 18-36VDC | 5VDC | DIL,SIL |
10 To 15 Watt Isolated DC-DC Converter,Wide 2 : 1 Input Range,Input Filter With Internal Capacitor
|
| B7-2412S10LF | Bothhand USA |
|
10W | 18-36VDC | 12VDC | DIL,SIL |
10 To 15 Watt Isolated DC-DC Converter,Wide 2 : 1 Input Range,Input Filter With Internal Capacitor
|