| model | brand | output power | Input voltage | Output voltage | package | describe | |
| RV-0509D/R6.4 | RECOM |
|
2W | 5VDC | ±9VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-0512D/R6.4 | RECOM |
|
2W | 5VDC | ±12VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-0515D/R6.4 | RECOM |
|
2W | 5VDC | ±15VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-123.3S/R6.4 | RECOM |
|
2W | 12VDC | 3.3VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1205S/R6.4 | RECOM |
|
2W | 12VDC | 5VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1209S/R6.4 | RECOM |
|
2W | 12VDC | 9VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1212S/R6.4 | RECOM |
|
2W | 12VDC | 12VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1215S/R6.4 | RECOM |
|
2W | 12VDC | 15VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-123.3D/R6.4 | RECOM |
|
2W | 12VDC | ±3.3VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1205D/R6.4 | RECOM |
|
2W | 12VDC | ±5VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1209D/R6.4 | RECOM |
|
2W | 12VDC | ±9VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1212D/R6.4 | RECOM |
|
2W | 12VDC | ±12VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1215D/R6.4 | RECOM |
|
2W | 12VDC | ±15VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-153.3S/R6.4 | RECOM |
|
2W | 15VDC | 3.3VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1505S/R6.4 | RECOM |
|
2W | 15VDC | 5VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1509S/R6.4 | RECOM |
|
2W | 15VDC | 9VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1512S/R6.4 | RECOM |
|
2W | 15VDC | 12VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1515S/R6.4 | RECOM |
|
2W | 15VDC | 15VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-153.3D/R6.4 | RECOM |
|
2W | 15VDC | ±3.3VDC | DIP24 |
● UL/CSA and EN-60950-1 Safety certified● EN-61010 for Test, Measurement and Lab Use● UL/CSA and EN-60601 for Medical Applications● 6.4kVDC or 8kV Reinforced Isolation● Optional Continuous Short Circuit Protection● Efficiency to 88%● Space Saving „Skinny DIP“ Package● Very Low Isolation Capacitance
|
| RV-1505D/R6.4 | RECOM |
|
2W | 15VDC | ±5VDC | DIP24 |