model brand PDF output power Input voltage Output voltage package describe
RP10-4812SE RECOM 10W 36-75VDC 12VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-4815SE RECOM 10W 36-75VDC 15VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-1205DE RECOM 10W 9-18VDC ±5VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-1212DE RECOM 10W 9-18VDC ±12VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-1215DE RECOM 10W 9-18VDC ±15VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-2405DE RECOM 10W 18-36VDC ±5VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-2412DE RECOM 10W 18-36VDC ±12VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-2415DE RECOM 10W 18-36VDC ±15VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-4805DE RECOM 10W 36-75VDC ±5VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-4812DE RECOM 10W 36-75VDC ±12VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-4815DE RECOM 10W 36-75VDC ±15VDC 2” x 1”
2:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● UL Certified● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 86 %
RP10-2405SEW RECOM 10W 9-36VDC 5VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-2412SEW RECOM 10W 9-36VDC 12VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-2415SEW RECOM 10W 9-36VDC 15VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-4805SEW RECOM 10W 18-75VDC 5VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-4812SEW RECOM 10W 18-75VDC 12VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-4815SEW RECOM 10W 18-75VDC 15VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-2405DEW RECOM 10W 9-36VDC ±5VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-2412DEW RECOM 10W 9-36VDC ±12VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %
RP10-2415DEW RECOM 10W 9-36VDC ±15VDC 2” x 1”
● 4:1 Wide Input Voltage Range● 10 Watts Output Power● 1.6kVDC Isolation● Fixed Operating Frequency● Six-Sided Continuous Shield● Standard 50.8 x25.4x10.2mm Package● Efficiency to 84 %